Turbulent intensity kinetic energy

Properties

  • based on the inlet-outlet condition
  • sets the turbulent kinetic energy based on the patch velocity and user-supplied turbulence intensity

    \[ k_p = 1.5 \left( I \mag{\u} \right)^2 \]

  • in the event of reverse flow, a zero gradient condition is applied, i.e.

    \[ \frac{d k}{d x} = 0 \]

Usage

The condition is specified in the field file using:

<patchName>
{
    type        turbulentIntensityKineticEnergyInlet;
    intensity   0.05;
    value       <field value>;

    // Optional entries
    U           U;
    phi         phi;
}

Further information

Source code:


Would you like to suggest an improvement to this page? Create an issue

Copyright © 2017 OpenCFD Ltd.

Licensed under the Creative Commons License BY-NC-ND Creative Commons License