reconstructPar(1)

www.openfoam.com, OpenFOAM-v2112

reconstructPar [OPTIONS]

Description

Reconstruct fields of a parallel case

Options

  • -allRegions
    Use all regions in regionProperties
  • -case dir
    Specify case directory to use (instead of cwd)
  • -constant
    Include the 'constant/' dir in the times list
  • -fields wordRes
    Specify single or multiple fields to reconstruct (all by default). Eg, 'T' or '(p T U "alpha.*")'
  • -lagrangianFields wordRes
    Specify single or multiple lagrangian fields to reconstruct (all by default). Eg, '(U d)' - Positions are always included.
  • -latestTime
    Select the latest time
  • -newTimes
    Only reconstruct new times (i.e. that do not exist already)
  • -no-fields
    Skip reconstructing fields
  • -no-lagrangian
    Skip reconstructing lagrangian positions and fields
  • -no-sets
    Skip reconstructing cellSets, faceSets, pointSets
  • -noZero
    Exclude the '0/' dir from the times list, has precedence over the -withZero option
  • -region name
    Use specified mesh region. Eg, -region gas
  • -regions wordRes
    Use specified mesh region. Eg, -regions gas Or from regionProperties. Eg, -regions '(gas "solid.*")'
  • -time ranges
    List of ranges. Eg, ':10,20 40:70 1000:', 'none', etc
  • -withZero
    Include the '0/' dir in the times list
  • -doc
    Display documentation in browser
  • -help
    Display short help and exit
  • -help-full
    Display full help and exit

ADVANCED OPTIONS

  • -debug-switch name=val
    Specify the value of a registered debug switch. Default is 1 if the value is omitted. (Can be used multiple times)
  • -fileHandler handler
    Override the file handler type
  • -info-switch name=val
    Specify the value of a registered info switch. Default is 1 if the value is omitted. (Can be used multiple times)
  • -lib name
    Additional library or library list to load (can be used multiple times)
  • -noFunctionObjects
    Do not execute function objects
  • -opt-switch name=val
    Specify the value of a registered optimisation switch. Default is 1 if the value is omitted. (Can be used multiple times)
  • -doc-source
    Display source code in browser
  • -help-compat
    Display compatibility options and exit
  • -help-man
    Display full help (manpage format) and exit
  • -help-notes
    Display help notes (description) and exit

COMPATIBILITY OPTIONS

  • -noFields (now -no-fields)
    The option was last used in 2106.
  • -noLagrangian (now -no-lagrangian)
    The option was last used in 2106.
  • -noSets (now -no-sets)
    The option was last used in 2106.

See Also

Online documentation https://www.openfoam.com/documentation/

Copyright

Copyright © 2018-2021 OpenCFD Ltd.